4. Operating procedure for regeneration inhibit mode
(1) Parked regeneration switch
(2)
DPF inhibit switch
(3) Engine warning indicator
(4) Regeneration indicator
(5) Parked regeneration indicator
(6) Engine rpm increase indicator
Regeneration operating procedure
1.
Start the engine.
2. Press the DPF inhibit switch , and the switch lamp illuminates.
Switch lamp “ON”: Regeneration inhibit mode selected.
Switch lamp “OFF”: Auto regeneration mode selected.
3.
When the parked regeneration indicator
starts flashing:
A specific amount of PM has accumulated in the DPF muf
fler.
Move the tractor to a safe place and activate the DPF muffler.
(See Operating procedure for parked regeneration on page 49.)
DIESEL PARTICULATE FILTER (DPF) MUFFLER  OPERATING THE ENGINE
LX2610,LX3310