2. Refill the recovery tank with water if necessary.
IMPORT
ANT :
• Do not fill the recovery tank above the
[FULL] mark.
• Add only coolant (mixture of water and
antifreeze).
(1) Recovery tank (A) FULL
(B)
LOW
3. If
the coolant level drops quickly, water may be
leaking somewhere, be sure to find the cause of
leakage.
5. Checking and refilling the oil in
the brake fluid reservoir
WARNING
T
o avoid personal injury or death:
• Only use the hydraulic oil that meets ISO VG 22.
Use of incorrect hydraulic oil will cause damage
to the brake system and potential brake failure.
1. Turn the starter switch to [RUN] position.
2. Check
whether the brake-fluid-warning-indicator
light up.
3. If the brake-fluid-warning-indicator light up, check
the brake-fluid reservoir and refill brake fluid up to a
height of 35 mm from the bottom.
(1) Brake fluid reservoir (2) Brake fluid warning indicator
(1) Brake fluid reservoir (A) 35 mm
IMPORTANT :
• If
a large amount of brake fluid has to be
refilled, check the brake system for leaks
before using the machine again.
• If the brake-fluid-warning-indicator lights up
a short time after adding brake fluid, there is
leak in the brake system.
The machine may only be started again after
the fault has been repaired.
6. Applying the grease to the grease
fittings
DANGER
T
o avoid serious personal injury or death:
• Keep clear of articulation joint during service
work.
WARNING
T
o avoid personal injury or death:
• Before greasing, always stop the engine, lower
the bucket and attachment to the ground,
release the hydraulic pressure in the hydraulic
PERIODIC SERVICE DAILY CHECK