Condition
GR10/GR25/GM10
L1, AS off or
on
Reconstructed carrier phase via C/A-code.
L2, AS off
Reconstructed carrier phase via P2-code.
L2, AS on
Switches automatically to patented P-code aided technique providing full L2 reconstructed carrier
phase.
GPS code measurements
Condition
GR10/GR25/GM10
L1, AS off
L1, AS on
Carrier phase smoothed code measurements: C/A-code.
L2, AS off
Carrier phase smoothed code measurements: P2-code and/or L2C code.
L2, AS on
Carrier phase smoothed code measurements: Patented P-code aided code and/or L2C code.
Carrier phase and code measurements on L1, L2 and L5 (GPS) are fully independent with AS on or off.
Code and Phase Measurement Precision (irrespective whether AS off/on)
Condition
GR10/GR25/GM10
Carrier phase L1 / L2 *
0.2mm rms / 0.2mm rms
Code (pseudorange) on L1 / L2 *
2cm rms / 2cm rms
* L5/E1/E5a/E5b/Alt-BOC values are expected to be similar to L1. Final values will be determined after initial operational