8400 StateLine C | Reference manual
Motor control (MCTRL)
Sensorless vector control (SLVC)
164 L Firmware 11.00 - DMS 8.0 EN - 10/2011
5.7.2.2 Torque control with speed limitation
For torque-controlled operation, a torque setpoint is defined in the drive system. Unlike the
Speed control with torque limitation
, this type of control has a deactivated speed
controller and torque limitation.
The torque setpoint is calculated directly from nTorqueSetValue_a.
The speed is defined by the process.
Due to its limitation, the speed-controlled drive can only rotate within a speed range
whose positive speed is limited by nSpeedHighLimit_a and whose negative speed is
limited by nSpeedLowLimit_a.
Identifier
DIS code | data type
Information/possible settings
nTorqueSetValue_a
C00830/27 | INT
Torque setpoint / additive torque
Scaling: 16384 100 % M
max
(C00057)
nSpeedHighLimit_a
C00830/88 | INT
Upper speed limit for speed limitation
(only for torque-controlled operation)
Scaling: 16384 100 % rated speed (C00011
)
nSpeedLowLimit_a
C00830/23 | INT
Lower speed limit for speed limitation
(only for torque-controlled operation)
Scaling: 16384 100 % rated speed (C00011
)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 StateLine C and is the answer not in the manual?

Lenze 8400 StateLine C Specifications

General IconGeneral
BrandLenze
Model8400 StateLine C
CategoryInverter Drive
LanguageEnglish

Related product manuals