10.10.2.3 Commissioning example
Task
An 8400 controller (node 2) which is configured as heartbeat consumer is to monitor
another 8400 controller (heartbeat producer, node 1).
The heartbeat producer is to transmit a heartbeat telegram to the heartbeat consumer
every 10 ms.
The heartbeat consumer monitors the heartbeat telegram for arrival. A response is to
be activated in the event of an error.
Parameterising the heartbeat producer (node 1)
1. Set the heartbeat producer time (C00381
) to 10 ms.
Parameterising the heartbeat consumer (node 2)
1. Set the CAN node address of the producer in C00385/1
.
2. Set the heartbeat consumer time in C00386/1
.
Note: The heartbeat consumer time must be greater than the heartbeat producer
time of the node to be monitored set in C00381
.
3. Set the desired response in C00592/5
which is to be activated should a heartbeat event
in the consumer occur.
Tip!
C00347/1...n
displays the heartbeat status of the monitored nodes.
Heartbeat telegram
The heartbeat telegram of the producer has the following identifier:
Identifier (COB-ID) = 1792 + producer's node address = 1792 + 1 = 1793 = 0x701
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 StateLine C and is the answer not in the manual?

Lenze 8400 StateLine C Specifications

General IconGeneral
BrandLenze
Model8400 StateLine C
CategoryInverter Drive
LanguageEnglish

Related product manuals