Firmware 11.00 - DMS 8.0 EN - 10/2011 L 865
8400 StateLine C | Reference manual
Function library
System blocks | LS_ParFree
16.2.15 LS_ParFree
This system block outputs 4 parameterisable 16-bit signals.
Outputs
Parameter
Identifier
Data type
Value/meaning
wPar1 ... wPar4
WORD
From version 11.00.00:
wC471_1 ... wC471_4
Output of the 16-bit signals parameterised in C00471/1...4
Note: From version 11.00.00 the outputs are named according to the respective
setting parameter for an easier allocation.
Parameter Possible settings Info
C00471/1...4
0x0000 0xFFFF Setting of the 16-bit signals to be
output
Z3DU
Z3DU
Z3DU
Z3DU
&
&
&
&