8400 StateLine C | Reference manual
Function library
Function blocks | L_Interpolator_1
Parameter
16.1.21.1 Signal interpolation
If signal interpolation is active (C00950/1 =1), the output signal will not reach the level of the
corresponding input signal until all interpolation steps parameterised in
C00951 have been performed:
[16-10] Signal characteristic
Parameter Possible settings Info
C00950/1
Signal interpolation of the dnPhIn_p
and nNIn_a input signals
Lenze setting: Off
Signal interpolation
( 805)
0Off
1On
C00950/2
Signal monitoring of the dnPhIn_p
input signal
Lenze setting: Off
Signal monitoring
( 806)
0Off
1On
C00951
1 65535 Number of interpolation steps
Corresponds to the receive cycle
of the data telegrams in [ms].
Lenze setting: 1
C00952
0 65535 Limit value for missing data
telegrams
Lenze setting: 5
Signal monitoring
( 806)
C00953
00Filters
In preparation!
n Setpoint signal
o Interpolated setpoint signal
p Receive cycle in [ms] = Number of interpolation steps (in our example: 5)
10515
t
ms
Dy from cycle 1
Dy from cycle 2
signal

cycle 1 cycle 2 cycle 3
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 StateLine C and is the answer not in the manual?

Lenze 8400 StateLine C Specifications

General IconGeneral
BrandLenze
Model8400 StateLine C
CategoryInverter Drive
LanguageEnglish

Related product manuals