Firmware 11.00 - DMS 8.0 EN - 10/2011 L 65
8400 StateLine C | Reference manual
Commissioning
Commissioning of the "Switch-off positioning" technology application
3.7.3 Parameterising the motor control
1. Go to Workspace and change to the Application parameters tab.
The motor control parameters, among other things, can be found on the left:
2. In the Motor control list field (C00006
), select the desired motor control.
3. Adapt the motor control parameters:
Related topics:
Notes on motor control
( 49)
Motor control (MCTRL)
( 106)
Parameter Lenze setting Info
Value Unit
V/f base frequency
(C00015
)
50.0 Hz Adapting the V/f base frequency
( 132)
Imax in motor mode
(C00022
)
47.00 A Optimising the Imax controller
( 136)
Vmin boost
(C00016
)
1.60 % Adapting the Vmin boost
( 134)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com