Firmware 11.00 - DMS 8.0 EN - 10/2011 L 843
8400 StateLine C | Reference manual
Function library
Function blocks | L_PCTRL_1
16.1.39.4 Evaluation of the output signal
After the limitation, the output signal is evaluated with the influencing factor
nInfluence_a. The evaluation is activated/suppressed along a ramp when the
bEnableInfluenceRamp input is set to TRUE. The ramp times are set with the parameters
"Influence acceleration time" (C00243
) and "Influence deceleration time" (C00244).
16.1.39.5 Comparison function "Actual value = setpoint"
If setpoint and actual value are identical and there is no system deviation, the bSetEqAct
status output is set to TRUE.
The hysteresis of the comparison function has a fixed value of 1 %.
From version 06.00.00, the symmetrical window around the setpoint for the
comparison function can be set in C00247
(Lenze setting: 2 %).
[16-20] Comparison function: Switching performance
[16-21] Comparison function: Example
n Hysteresis (1 %, fixed value)
o C00247
: Window
TRUE
FALSE
bSetEqAct
Set value
Act value

n Hysteresis (1 %, fixed value)
o C00247
: Window
Act value
Set value
TRUE
FALSE
bSetEqAct
t
t
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 StateLine C and is the answer not in the manual?

Lenze 8400 StateLine C Specifications

General IconGeneral
BrandLenze
Model8400 StateLine C
CategoryInverter Drive
LanguageEnglish

Related product manuals