Firmware 11.00 - DMS 8.0 EN - 10/2011 L 97
8400 StateLine C | Reference manual
Device control (DCTRL)
Automatic restart after mains connection/fault...
4.3 Automatic restart after mains connection/fault...
.../Error/undervoltage/loading of the Lenze setting
In C00142
, the starting performance of the controller after mains connection,
undervoltage, loading of the Lenze setting as well as a "Trouble
" or a "Fault" reset can be
parameterised individually:
4.3.1 "Inhibit at power-on" auto-start option
The auto-start option "Inhibit at power-on" prevents the change to the "SwitchedOn
"
status after mains connection if the controller is already enabled at mains connection.
The following three cases describe the behaviour of the controller after mains connection
depending on whether the controller is enabled and the set auto-start option. Here, it is
assumed that after mains connection, no errors and trouble occur in the controller and the
"EnableOperation" control bit in the wDriveControl is set to "1".
Auto-start option (C00142) Lenze setting
Bit 0 "Inhibit at power-on" auto-start option
1 Inhibit is active
Bit 1 Inhibit at trouble 0 Inhibit is not active
Bit 2 Inhibit at fault 0 Inhibit is not active
Bit 3 Inhibit at undervoltage 1 Inhibit is active
Bit 4 Auto-start option "Inhibit at Lenze setting"
(from version 06.00.00)
1 Inhibit is active
Bit 5 Reserved 0
Bit 6
Bit 7
Note!
In the Lenze setting , automatic restart after mains connection, undervoltage,
and loading of the Lenze setting is inhibited.
Danger!
If the "Inhibit at power-on" auto-start option has been deactivated in C00142,
(bit 0 = 0), the motor can directly start to run if the controller is enabled after
mains connection!
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 StateLine C and is the answer not in the manual?

Lenze 8400 StateLine C Specifications

General IconGeneral
BrandLenze
Model8400 StateLine C
CategoryInverter Drive
LanguageEnglish

Related product manuals