8400 StateLine C | Reference manual
Device control (DCTRL)
Automatic restart after mains connection/fault...
98 L Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Case 1: No controller enable at mains connection
If the controller is not enabled at mains connection, the controller remains in the
"SwitchedOn
" status. Only with the controller enable, the status changes to the
"OperationEnabled
" status, independent of the set auto-start option:
Case 2: Controller enable at mains connection and "Inhibit at power-on" activated
If the controller is enabled at mains connection and the auto-start option "Inhibit at power-
on" is activated, the controller remains in the "ReadyToSwitchOn
" status. For changing to
the "SwitchedOn
" status, the controller enable must first be deactivated. Only when the
controller is enabled again afterwards, the status changes to "OperationEnabled
":
Case 3: Controller enable at mains connection and "Inhibit at power-on" deactivated
If the "Inhibit at power-on" auto-start option is deactivated in C00142
(bit 0 = 0), the
status first changes from "ReadyToSwitchOn
" to "SwitchedOn" and then to
"OperationEnabled
" after mains connection with enabled controller: