8400 StateLine C | Reference manual
Commissioning
Commissioning of the "Switch-off positioning" technology application
66 L Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
3.7.4 Parameterising the application
The application parameters can be found on the right side of the Application parameter
tab:
1. Select the "switch-off positioning" mode in the Application (C00005
) list field.
– After the "Switch-off positioning" application is selected, the contents of the tab
change, e.g. the Process controller and Motor potentiometer buttons are not shown
any more.
2. In the Control mode list field (C00007
) and in case of illustration [3-2], for the shown
switch-off positioning without
pre-switch off the "Terminals 2" control mode must be
selected.
– The corresponding wiring diagram is displayed in a pop-up window if you click the
button right to the list field.
– For a detailed description, see the chapter "Terminal assignment of the control
modes". ( 302)