8400 StateLine C | Reference manual
Device control (DCTRL)
Device commands (C00002/x)
84 L Firmware 11.00 - DMS 8.0 EN - 10/2011
4.1.6 Reset error
The C00002/19
= "1: On / start" device command acknowledges an existing error message
if the error cause has been eliminated and thus the error is not pending anymore.
After the reset (acknowledgement) of the current error, further errors may be pending
which must also be reset.
The status determining error is displayed in C00168
.
The current error is displayed in C00170
.
Tip!
An error message can also be acknowledged by activating the Reset error button in
the Diagnostics tab.
Detailed information on error messages can be found in the "Diagnostics & error
management" chapter. ( 380)
4.1.7 Delete logbook
The C00002/21
= "1: On / start" device command deletes all logbook entries.
Tip!
Click the Logbook button in the Diagnostics tab to display the logbook in the
»Engineer«.
In the Logbook dialog box, it is also possible to delete all logbook entries by clicking
the Delete button.
Detailed information on the logbook can be found in the "Diagnostics & error
management" chapter. ( 380)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 StateLine C and is the answer not in the manual?

Lenze 8400 StateLine C Specifications

General IconGeneral
BrandLenze
Model8400 StateLine C
CategoryInverter Drive
LanguageEnglish

Related product manuals