Firmware 11.00 - DMS 8.0 EN - 10/2011 L 77
8400 StateLine C | Reference manual
Device control (DCTRL)
Device commands (C00002/x)
Activate device command
When an online connection has been established, simply use the »Engineer« to activate a
device command by selecting the corresponding option from the Parameters tab in
C00002/x
("0: off" or "1: On / start").
Alternatively, the device command can also be activated via e.g. keypad or through a
master control by writing to C00002/x
.
Some of the frequently used device commands (such as "Save parameter set") can also
be executed via the Toolbar icons of the »Engineer« when an online connection has
been established:
Symbol Function
Enable controller
Inhibit controller
Save parameter set (for 8400: Save all parameter sets)
Note!
Device commands that can be executed via the Toolbar of the »Engineer« always
affect the element currently selected in the Project view including all
subelements!
If no controller but e.g. a system module is selected in the Project view
instead, the corresponding device command will be activated in all lower-
level controllers that have an online connection to the »Engineer«.
Before the desired action is carried out, a confirmation prompt appears first,
asking whether the action is really to be carried out.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 StateLine C and is the answer not in the manual?

Lenze 8400 StateLine C Specifications

General IconGeneral
BrandLenze
Model8400 StateLine C
CategoryInverter Drive
LanguageEnglish

Related product manuals