 UMX-TPS-TX100 series – User's Manual 144

Sending a TCP Text (ASCII-format)
ç <IP_address>:<port_no>=<text>)
Sending a TCP Binary Message (HEX-format)
ç <IP_address>:<port_no>=<HEX_message>)
Sending a UDP Message (ASCII-format)
ç <IP_address>:<port_no>=<message>)
Sending a UDP Text (ASCII-format)
ç <IP_address>:<port_no>=<text>)
Sending a UDP Binary Message (HEX-format)
ç <IP_address>:<port_no>=<HEX_message>)
HTTP Messaging
Setting the Target IP Address
ç <IP_address>
Setting the TCP Port
ç <port_no>
Setting the Target Path
ç <path>
Setting the Message Header
ç <header_text>
Sending a Post Message
ç <body_text>)
Sending a Put Message
ç <body_text>)
TCP Message Recognizer
Setting the IP Address of the TCP Server
ç <loc>.ServerIP=<IP_address>

ç <loc>.ServerPort=<port_no>
Connecting to a TCP Server
ç <loc>:connect()
Disconnecting from a TCP Server
ç <loc>:disconnect()
Setting the Delimiter Hex
ç <loc>.DelimiterHex=<delimiter>
Setting the Timeout
ç <loc>.TimeOut=<timeout>

ç <loc>.Rx

ç <loc>.RxHex

ç <loc>:clear()

ç <loc>.ActiveRx

ç <loc>.ActiveRxHex
Set the Active Timeout
ç <loc>.ActivePropertyTimeout=<a_timeout>
Running an Immediate Event Action
ç <loc>.ActionTrigger=<event_nr>

Protocol Setting
ç <port>.ControlProtocol=<protocol>
BAUD Rate Setting
ç <port>.Baudrate=<baudrate>
Databits Setting
ç <port>.DataBits=<databits>
Stopbits Setting
ç <port>.StopBits=<stopbits>
Parity Setting
ç <port>.Parity=<parity>
RS-232 Operation Mode
ç <port>.Rs232Mode=<mode>
Command Injection Enable
ç <port>.CommandInjectionEnable=<logical_value>

Table of Contents

Other manuals for Lightware UMX-TPS-TX100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware UMX-TPS-TX100 Series and is the answer not in the manual?

Lightware UMX-TPS-TX100 Series Specifications

General IconGeneral
BrandLightware
ModelUMX-TPS-TX100 Series
CategoryTransmitter
LanguageEnglish

Related product manuals