Technical Information
116
PW 6xx7
Service mode (service level)
3 Service settings
1 Basic settings
12 Telephone
1 Service telephone number Display Explanation
“Telephone:
___________________”,
Set of permissible
characters, Delete
symbol, Save symbol,
Back symbol
Field can be populated
with a maximum of 20
alphanumeric characters,
e.g.,
SERVICE05241899999”.
This will appear with fault
messages in the display
when the operator presses
the button under the
information I icon. Factory
setting: 20 empty spaces.
Table 100-93: Telephone Programming
After selecting the characters with the multifunction selector switch, confirm
with the OK button.
Delete characters by using the button under the backspace symbol (clear and
go back one character).
Save the telephone number by pressing and releasing the Save button.
Pressing the Back button quits without saving and goes back one menu
level.
The service technician can configure programmable multifunction modules
using a list of input and output functions, reassign defective or additional
signal inputs/outputs to unused inputs/outputs without installing a new
multifunction module, or create a new multifunction module (within limits) to
meet the customer's needs.
Service mode (service level)
3 Service settings
2 Programmable MFM
1 Input
2 Output
Table 100-94: Programmable MFM
Make a selection with the multifunction selector switch and confirm with the
OK button. The Back button can be pressed to go back one menu level.
The service technician can configure programmable multifunction modules
with input functions and output functions using a function list. Each input (1 to
11) is mapped to an input function, and each output (1 to 9) to an output
function.
Service mode (service level)
3 Service settings
2 Programmable MFM
1 Input
1 Flow meter (impeller) 1
2 Flow meter (impeller) 2
3 Flow meter (impeller) 3
4 Flow meter (impeller) 4
5 Empty message 1
6 Empty message 2
7 Empty message 3