Technical Information
45
PW 6xx7
Figure 100-7: Speed/Time Diagram for Automatic Spin Setting
Ph1
Phase 1, pre-extraction, time 1 min 0 s, rhythm “No”, speed 500 rpm
Ph2
Phase 2, loosening, time 1 min 0 s, rhythm “12/3”, speed 30 rpm
Ph3
Phase 3, initial spin, time 1 min 0 s, rhythm “No”, speed 500 rpm
Ph4
Phase 4, spin, time 3 min 0 s, rhythm “No”, speed 850 rpm
Ph5
Phase 5, final spin, time 3 min 0 s, rhythm “No”, maximum permitted spin speed for
model
Ph6
Phase 6, loosening, time 2 min 0 s, rhythm “12/3”, speed 30 rpm
max.
Maximum permitted spin speed selection; see also Table 100-18.
Phase Time Rhythm Speed [rpm]
Phase 1 (Ph1) 1 min 0 s No 500
Phase 2 (Ph2) 1 min 0 s 12s on / 3 s off 30
Phase 3 (Ph3) 1 min 0 s No 500
Phase 4 (Ph4) 3 min 0 s No 850
Phase 5 (Ph5) 3 min 0 s No Maximum permitted speed; see Table
100-18
Phase 6 (Ph6) 2 min 0 s 12s on / 3 s off 30
Table 100-17: Spin Phases 1 to 6 for Automatic Spin Profile
Maximum selectable spin speed for different models:
Model Maximum spin speed
PW 6107 1200 rpm
PW 6137 1100 rpm
PW 6167 1150 rpm
PW 6207 1100 rpm
Table 100-18: Maximum Selectable Spin Speed for Different Models
For further details and setting options, see Section 100-4.4.