Item Description Options Details
16 Peak load Yes / No
High load peaks in electrical systems can
result in particularly high energy costs.
With major installations, a peak-load cut-
out feature avoids these extra charges for
load peaks. A monitoring system
registers current consumption and when
this is too high, a cutout signal is
produced. Machine response: Heating is
switched off and program may possibly
be interrupted. When monitoring system
resets signal, wash program continues
automatically. This setting determines if
heating will be switched off by a peak-
load signal being received at the Peak
load input. Default setting: Yes. If control
registers that header of program in
operation permits peak-load cutout and
program is currently in a heating step
when a peak-load signal is received, then
heating is switched off, program is
stopped and display shows Prog.
stopped. Peak load cut-out. Program
will start again automatically. Control
also corrects program finish time. If a
heating stage is not operating, no
message is displayed. Peak-load cutout
does not have an overriding time control.
17 Hot water control Yes / No
With Yes setting and water intake control
set to Automatic, water inlet valves are
operated in a certain way. If possible,
control will attempt to achieve target
wash temperature during first water
intake by operating cold- and hot- water
valves alternately. Without water intake
control set to Automatic, control opens
programmed valves until target
temperature is reached and then
switches to cold-water intake only.
Default setting: No.
18 Price
No / 0.10; 0.20; ...
9999.90 in 0.10
steps
Price of a wash program is set on models
with a payment system. No charge or a
price between 0.10 currency units to
9999.90 currency units can be set.
Default setting: No.
Table 100-21: Internal Structure of Program Header for a Profitronic M Washing
Program
Block programming - Profitronic M washing control:
No. Program Step Basic Options Setting Options Notes
0 Block name 20 blank spaces
All available
alphanumeric and
special
characters
For naming block 1. Max. length
20 characters, e.g., Pre-wash
1 Block activation No
No
Program block will be skipped
before and during program.
Permanent
Program block will always be
carried out during program.
Block +
Program block will only be carried
out when Block + button is
activated before program start or
during program before block
would be started; otherwise,
block will be skipped.

Table of Contents

Other manuals for Miele PW 6207

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele PW 6207 and is the answer not in the manual?

Miele PW 6207 Specifications

General IconGeneral
BrandMiele
ModelPW 6207
CategoryWasher
LanguageEnglish

Related product manuals