Technical Information
77
PW 6xx7
No. Program Step Basic Options Setting Options Notes
31
Drainage path
2
Drain (route for
water extracted in
spin cycle)
No
No drainage takes place. If No is
selected, a spin speed > 70 rpm
cannot be set in the Spin
program segment. Spinning with
water is prevented.
Drain Activation of the drain valve.
Reservoir
Drained water is transferred to
the water recycling (WRG) tank.
Empty reservoir
The control empties the water
recycling tank by opening the
water recycling intake (K6), drain
valve (AVauf) and water
recycling (WRGauf) valves.
Cleaning
Water is pumped into the water
recycling (WRG) tank and
returned to the machine.
32
Free spin
speed selection
No
No
Control carries out spin cycle
with spin speed programmed for
this table/block.
Yes
Machine spins with most recently
set spin speed selected by
operator before program start,
providing this is not greater than
speed programmed for this block.
33 Spin No
No No spin carried out.
Automatic
Control carries out an automatic
spin with 6 phases based on:
Pre-spin, loosening with
redistribution, spin with
increasing spin speeds 500 rpm,
850 rpm, final spin speed,
loosening. For details, see
Sections 100-2.9 and 100-4.4.
User-defined
Programmer creates a spin cycle
with 6 phases. Each individual
phase is programmed with three
settings for “Time”, “Rhythm” and
“Speed”. For details, see tables
in Section 100-4.4.
34 Repeat No
No
This block will not be repeated in
either associated program
segment (e.g., pre-wash, main
wash or rinse) or complete
program.
“n” x block
“n” can be selected from 1 to 9
inclusive. This block will then be
repeated n times in program area
to which it belongs.
“m” x program
“m” can be selected from 1 to 9
inclusive. All blocks that have
been carried out until now since
program start (including this
block) will be repeated m times,
i.e. program up to and including
this block will be repeated m
times.
35
Block end
signal
1
Yes
No
Control does not provide a block-
end signal.
Yes
Provision of a block-end signal
for 0.5 s at Block end signal
output when drum is stationary.
Table 100-22: Block Programming
1
With payment system operation, Yes must be programmed in the last block of the complete
program to provide a reset signal to the payment system indicating that the program has finished.