Technical Information
80
PW 6xx7
Program area Program block Actual temperature = Target temperature
1 (pre-wash) only 1 block 1 WD, W1, K1
1 (pre-wash) with 2 to 10 blocks 1 WD, W1, K1
2 to 10 WD, K1
2 (main wash) only 1 block without pre-wash 1 WD, W2, K2
2 (main wash) with 1 to 10 blocks with pre-wash 1 to 10 WD, W2, K2
3 (rinse) 1 KH, WD, K3
3 (rinse) with 2 blocks 1 KH, WD, K4
2 KH, WD, K3
3 (rinse) with 3 blocks 1 KH, WD
2 KH, WD, K4
3 KH, WD, K3
3 (rinse) with 4 to 10 blocks 1 KH, WD
2 KH, WD, K4
3 to 9 KH, WD
10 (last) KH, WD, K3
Table 100-26: Valve Activation Summary - Automatic Water Intake Setting, Part 2
Valve activation summary - Automatic water intake setting, with setting Hot
water control = No, part 3:
Program area Program block Actual temperature < Target temperature
and Hot water control = No
1 (pre-wash) only 1 block 1 WD, W1, K1
1 (pre-wash) with 2 to 10 blocks 1 WD, W1, K1
2 to 10 WD, W1
2 (main wash) only 1 block without pre-wash 1 WD, W2, K2
2 (main wash) with 1 to 10 blocks with pre-wash 1 to 10 WD, W2
3 (rinse) 1 WD, K3
3 (rinse) with 2 blocks 1 WD, K4
2 WD, K3
3 (rinse) with 3 blocks 1 WD
2 WD, K4
3 WD, K3
3 (rinse) with 4 to 10 blocks 1 WD
2 WD, K4
3 to 9 WD
10 (last) WD, K3
Table 100-27: Valve Activation Summary - Automatic Water Intake Setting, Part 3
Valve activation summary - Automatic water intake setting, with setting Hot
water control = Yes, part 4:
Program area Program block Actual temperature < Target temperature
and Hot water control = Yes
1 (pre-wash) only 1 block 1 WD, W1
1 (pre-wash) with 2 to 10 blocks 1 WD, W1
2 to 10 WD, W1
2 (main wash) only 1 block without pre-wash 1 WD, W2
2 (main wash) with 1 to 10 blocks with pre-wash 1 to 10 WD, W2
3 (rinse) 1 WD, K3
3 (rinse) with 2 blocks 1 WD, K4
2 WD, K3
3 (rinse) with 3 blocks 1 WD
2 WD, K4
3 WD, K3
3 (rinse) with 4 to 10 blocks 1 WD
2 WD, K4
3 to 9 WD
10 (last) WD, K3
Table 100-28: Valve Activation Summary - Automatic Water Intake Setting, Part 4