Configuring the job computer
Calibrating the flow meter
⇨ The following screen appears:
5. - Start application.
⇨ During application, the number of pulses will be counted on the "CALIBRATION – Main flow
meter" screen.
6. Apply a few hundred litres. Do not fully empty the tank. This prevents air bubbles from forming
and distorting the results.
7. - Stop application.
⇨ The application will be stopped.
⇨ No pulses are counted on the display.
8. - Stop calibration.
9. Weigh the tank.
10. Enter the applied quantity in litres on the "Enter water volume" line.
11. - Exit screen.
⇨ You have calibrated the flow meter with the tank method.
Calibrating the flow meter with the nozzle method
When calibrating the flow meter using the nozzle method, you determine the average quantity of the
liquid applied through a nozzle in a specific time.
When calibrating using this method, you must apply clean water over the entire working width and
measure the applied quantity on different nozzles using a measuring cup.
The flow meter measures the pulses during this time.
When you have finished the application, you must enter how much water was applied on average by
one nozzle in one minute.
The computer calculates the number of pulses per litre.