EasyManuals Logo
Home>Omron>Servo Drives>G5 Series

Omron G5 Series User Manual

Omron G5 Series
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #306 background imageLoading...
Page #306 background image
6 Applied Functions
6 - 24
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
6-7-2 Parameters Requiring Settings
Parameter
No.
Name Description Reference
Pn114 Gain Switching Input
Operating Mode Selection
Set to enable or disable the gain switching function. P.7-13
Position control mode
Pn115 Switching Mode in Position
Control
Set the condition for switching between Gain 1 and Gain 2. P.7-14
Pn116 Gain Switching Delay Time
in Position Control
Set the time to return from Gain 2 to Gain 1.
(Unit: 0.1 ms)
P.7-15
Pn117 Gain Switching Level in
Position Control
Set the judgment level for switching between Gain 1 and Gain 2. P.7-16
Pn118 Gain Switching Hysteresis
in Position Control
Set the hysteresis width to be used for the judgment level set in
Gain Switching Level (Pn117).
P.7-16
Pn119 Position Gain Switching
Time
Set the time to change gradually from low to high gain.
(Unit: 0.1 ms)
P.7-16