8 - 3
8 Operation
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
8-2 Preparing for Operation
8
8-2-1 Items to Check Before Turning ON the
Power Supply
8-2 Preparing for Operation
This section explains the procedure to prepare the Servomotor and Servo Drive for operation on
completion of installation and wiring. It explains items to check both before and after turning ON the
power supply.
• Check to be sure that the power supply voltage is within the ranges shown below.
R88D-KP01H/02H/04H/08H/10H/15H (Single-phase or single-phase/3-phase 200 VAC input)
Main circuit power supply: Single-phase or single-phase/3-phase 200 to 240 VAC (170 to 264 VAC)
50/60 Hz
Control circuit power supply: Single-phase 200 to 240 VAC (170 to 264 VAC) 50/60 Hz
R88D-KP20H/30H/50H (3-phase 200 VAC input)
Main circuit power supply: 3-phase 200 to 230 VAC (170 to 253 VAC) 50/60 Hz
Control circuit power supply: Single-phase 200 to 230 VAC (170 to 253 VAC) 50/60 Hz
• The main circuit power supply inputs (L1/L3 or L1/L2/L3) must be properly connected to the terminal
block.
• The control circuit power supply inputs (L1C/L2C) must be properly connected to the terminal block.
• The Servomotor’s red (U), white (V), and blue (W) power lines and the green/yellow ( ) must be
properly connected to the terminal block.
• There should be no load on the Servomotor. (Do not connect the mechanical system.)
• The Servomotor side power lines and the power cables must be securely connected.
• The encoder cable must be securely connected to the encoder connector (CN2) of the Servo Drive.
• The encoder cable must be securely connected to the encoder connector of the Servomotor.
• The control cable must be securely connected to the control I/O connector (CN1).
• The Operation Command (RUN) signal is OFF.
8-2-1 Items to Check Before Turning ON the Power Supply
Checking Power Supply Voltage
Checking Terminal Block Wiring
Checking the Servomotor
Checking the Encoder Wiring
Checking the Control I/O Connector

Table of Contents

Other manuals for Omron G5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron G5 Series and is the answer not in the manual?

Omron G5 Series Specifications

General IconGeneral
BrandOmron
ModelG5 Series
CategoryServo Drives
LanguageEnglish

Related product manuals