Setting Conditions for Communications with Host by Using Memory Switches Section 6-7
6-7-5 Setting the Memory Link Method
Set the communications conditions for the host link method at serial port A or
serial port B by following the operation from the System Menu shown below.
Check the communications settings of the host to be used.
Select Maintenance Mode.
Select Memory Switch.
In this example, serial port A is used.
Ver 4.12
Display the fourth memory switch screen by
pressing the [↓] (next screen) or [↑]
(previous screen) touch switch.
Press the touch switch corresponding to the
port at which the memory link method is to
be set (Comm. A Method or Comm. B
Method) to display the setting option
Memory Link.
The setting option changes each time the
touch switch is pressed.In this example,
serial port A is used.
Press the Set touch switch to the right of the
port at which the setting has been made.