186
System Settings Section 6-9
6-9-12 Setting the Time-out Interval
The NT31/NT31C goes into the time-out error status if no response is
received from the host within a fixed time. The Time-out Interval setting speci-
fies the time lapse at which time-out is judged to have occurred.
The setting range is 1 to 10 seconds. The default (factory) setting is 1 second.
Reference: Whether or not an error screen is displayed when a time-out error occurs is de-
termined by the setting for the Comm. Auto-return memory switch.
Set the time-out interval by following the menu operation from the System
Menu shown below.
To set other memory switches, select the relevant screen using the [ ] (next
screen) or [ ] (previous screen) touch switch, then make the setting.
Select Maintenance Mode.
Select Memory Switch.
01 02 03 .... 09 10 01 ....
Ver 4.12
Press [↓] (next screen) or [↑] (previous
screen) to display the third memory
switch setting screen.
Press Time-out Interval to display the
required time lapse.
The setting option changes each
time the touch switch is pressed,
according to the following sequence.