7 - 11
7 Applied Functions
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
7-2 General-purpose Output Signals
7
7-2-3 Function Output Details
This section explains the function outputs that can be allocated to the general-purpose outputs.
Error Output (ERR)
This output is turned OFF when the Servo Drive detects an error.
This output is OFF when the power supply is turned ON, but the output turns ON when the Servo
Drive’s initial processing is completed.
Servo Ready Output (READY)
This output signal indicates the Servo Drive is ready to supply power to the Servomotor.
It turns ON when no error is detected after the main circuit power supply turns ON.
Position Completion Output (INP1 and INP2)
INP1 will turn ON when the following error is less than or equal to Positioning Completion Noti-
fication - Position Window (3B51-01 hex).
INP2 output will turn ON as specified in the Positioning Completion Notification 2 - Notifica-
tion Condition (3B52-02 hex).
This output remains OFF in controls other than position control.
4657 Velocity Conformity Out-
put
0 No allocation 0 Positive logic (NO
contact)
4658 Warning Output 1 0 No allocation 0 Positive logic (NO
contact)
4659 Warning Output 2 0 No allocation 0 Positive logic (NO
contact)
465A Velocity Limiting Output 0 No allocation 0 Positive logic (NO
contact)
465B Error Clear Attribute Out-
put
0 No allocation 0 Positive logic (NO
contact)
465C Remote Output 1 2 General Output 2
(OUT2)
0 Positive logic (NO
contact)
465D Remote Output 2 4 General Output 3
(OUT3)
0 Positive logic (NO
contact)
465E Remote Output 3 0 No allocation 0 Positive logic (NO
contact)
465F Zone Notification Output
1
0 No allocation 0 Positive logic (NO
contact)
4660 Zone Notification Output
2
0 No allocation 0 Positive logic (NO
contact)
4661 Position Command Sta-
tus Output
0 No allocation 0 Positive logic (NO
contact)
4662 Distribution Completed
Output
0 No allocation 0 Positive logic (NO
contact)
4663 External Brake Interlock
Output
0 No allocation 0 Positive logic (NO
contact)
7-2-3 Function Output Details
Index (hex) Name
Default setting
Subindex 01 hex
Port Selection
Subindex 02 hex
Logic Selection
Set value Status Set value Status

Table of Contents

Other manuals for Omron R88D-1SN ECT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-1SN ECT Series and is the answer not in the manual?

Omron R88D-1SN ECT Series Specifications

General IconGeneral
BrandOmron
ModelR88D-1SN ECT Series
CategoryController
LanguageEnglish

Related product manuals