7 - 11
7 Applied Functions
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
7-2 General-purpose Output Signals
7
7-2-3 Function Output Details
This section explains the function outputs that can be allocated to the general-purpose outputs.
Error Output (ERR)
• This output is turned OFF when the Servo Drive detects an error.
• This output is OFF when the power supply is turned ON, but the output turns ON when the Servo
Drive’s initial processing is completed.
Servo Ready Output (READY)
• This output signal indicates the Servo Drive is ready to supply power to the Servomotor.
• It turns ON when no error is detected after the main circuit power supply turns ON.
Position Completion Output (INP1 and INP2)
• INP1 will turn ON when the following error is less than or equal to Positioning Completion Noti-
fication - Position Window (3B51-01 hex).
• INP2 output will turn ON as specified in the Positioning Completion Notification 2 - Notifica-
tion Condition (3B52-02 hex).
• This output remains OFF in controls other than position control.
4657 Velocity Conformity Out-
put
0 No allocation 0 Positive logic (NO
contact)
4658 Warning Output 1 0 No allocation 0 Positive logic (NO
contact)
4659 Warning Output 2 0 No allocation 0 Positive logic (NO
contact)
465A Velocity Limiting Output 0 No allocation 0 Positive logic (NO
contact)
465B Error Clear Attribute Out-
put
0 No allocation 0 Positive logic (NO
contact)
465C Remote Output 1 2 General Output 2
(OUT2)
0 Positive logic (NO
contact)
465D Remote Output 2 4 General Output 3
(OUT3)
0 Positive logic (NO
contact)
465E Remote Output 3 0 No allocation 0 Positive logic (NO
contact)
465F Zone Notification Output
1
0 No allocation 0 Positive logic (NO
contact)
4660 Zone Notification Output
2
0 No allocation 0 Positive logic (NO
contact)
4661 Position Command Sta-
tus Output
0 No allocation 0 Positive logic (NO
contact)
4662 Distribution Completed
Output
0 No allocation 0 Positive logic (NO
contact)
4663 External Brake Interlock
Output
0 No allocation 0 Positive logic (NO
contact)
7-2-3 Function Output Details
Index (hex) Name
Default setting
Subindex 01 hex
Port Selection
Subindex 02 hex
Logic Selection
Set value Status Set value Status