9 Details on Servo Parameters
9 - 122
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Sets the Monitor Input 8 (MON8).
9-15-17 463F hex: Monitor Input 8
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size Access
PDO
map
Complete
access
Modes of
operation
463F --- Monitor Input 8 --- --- --- --- --- --- --- Possible ---
00 Number of
entries
--- --- 81 hex --- 1 byte
(U8)
RO --- --- ---
01 Port Selection 0 to 8 --- 0 R 4 bytes
(INT32)
RW --- --- ---
02 Logic Selection 0 to 1 --- 0 R 4 bytes
(INT32)
RW --- --- ---
81 Signal Status --- --- --- --- 4 bytes
(INT32)
RO --- --- ---