9 Details on Servo Parameters
9 - 32
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Sets the following performance for the target velocity.
The higher the gain is, the higher the following performance of the internal command is for the target
velocity.
The set value is valid when
TDF Velocity Control - Command Following Gain Selection (3120-10
hex) is set to 0 (use the Command Following Gain).
Selects the command following gain switching method.
Description of Set Values
Sets the cutoff frequency to the velocity command.
The higher the set value is, the higher the following performance of the internal command is for the
target velocity.
The set value is valid when TDF Velocity Control - Command Following Gain Selection (3120-10
hex) is set to 1 (use the Command Following Gain 2).
Subindex 01 hex: Command Following Gain
Subindex 10 hex: Command Following Gain Selection
Set
value
Description
0 Use the Command Following Gain.
1 Use the Command Following Gain 2.
Subindex 11 hex: Command Following Gain 2

Table of Contents

Other manuals for Omron R88D-1SN ECT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-1SN ECT Series and is the answer not in the manual?

Omron R88D-1SN ECT Series Specifications

General IconGeneral
BrandOmron
ModelR88D-1SN ECT Series
CategoryController
LanguageEnglish

Related product manuals