Checking/Adjusting the Measurement - ADJ Mode
ZFX-C User’s Manual
4
FUNCTIONS USED DURING OPERATION
129
Switching the Image Display Method
In the Individual results display or Position correction display, you can hide or reduce the size of images that
are displayed simultaneously with measurement information. Each press of the ↑ UP key/↓ DOWN key
switches the image display as follows:
In the Stored image display, the image display is switched between 1/4 display and full display.
In the "Variables list," "Data list" or "Judgments list" display, each press of the ↑ UP key/↓ DOWN key toggles
display/hide of the camera image.
Using a Saved Image to Perform Re-measurement
Re-measurement can be performed using a measurement image saved in internal memory. Images are saved
to internal memory in the RUN mode. If the ← L key/→ R key is pressed in the Individual results display or All
results/Region display, the screen switches to the saved image and re-measurement is executed.
Up to 100 images can be saved. Images that were judged as NG also can be saved.
Measurement Image Save Conditions, p.147
Previous Next
Display sw
Adjust
Individual result
TEA
Previous Next
Display sw
Adjust
Individual result
TEA
Prev. Next
Display sw
Adjust
Individual result
Camnera 0
0.Bank00
0.Pattern Search
Judge OK
Correlation 92
Position X 462
Position Y 352
Angle 15
OK
353ms
Camnera 0
0.Bank00
0.Pattern Search
Judge OK
Correlation 92
Position X 462
Position Y 352
Angle 15
OK
353ms
Camnera 0
0.Bank00
0.Pattern Search
Judge OK
Correlation 92
Position X 462
Position Y 352
Angle 15
OK
353ms
1/4 display
Full display
No image
The 1/4 display is available only
for the individual results display
and position correction display.
The image is not displayed
while a saved image is dis-
played.