Mounting and Connecting Devices
ZFX-C User’s Manual
1
BEFORE USE
25
Installing the Controller
Installation Precautions
To improve heat radiation, install the Controller only in the orientation show below.
Do not install the Controller in the following orientations.
• Install the Controller so that the distance between the Controller and other devices is at least the dimensions shown
in the figure below to improve the ventilation.
• Keep the ambient temperature less than 50 °C. If the ambient temperature is higher than 50 °C, install a fan forced
cooling system or an air conditioner to keep the temperature lower than 50 °C.
• Avoid mounting on a panel, in which high-voltage emitting devices are installed to prevent ZFX-C operation from
being affected by noise.
• Allow at least 10 m between the Controller and power lines to keep noise at a low level in the operating environ-
ment.