EasyManuals Logo
Home>Omron>Accessories>ZFX-C

Omron ZFX-C User Manual

Omron ZFX-C
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
Timing Charts
ZFX-C User’s Manual
6
PARALLEL INTERFACE
171
Commands Other than for Measurement
Bank switching/Bank group switching/Model re-registration
Explanation of operation
(1) The command input is accepted only in the RUN mode.
T1:
Executing trigger delay
time
This is the delay time until the execution trigger DI8 is input after commands are set to DI0
to DI7. 5 ms or more.
T2:
Executing trigger ON
time
5 ms or more
T3:
Execution delay time
0.5 ms or less
T4:
ENABLE OFF time
This time varies depending on settings for banks, bank groups, model registration.
OFF
ON
T2
RUN
DI8
T1
T3
T4
(1)
OFF
ON
OFF
ON
OFF
ON
ENABLE
DI
0 to 7