System Settings
148
ZFX-C User’s Manual
Handling the ENABLE Signal
Set how the ENABLE signal is handled.
ENABLE signal
Operation when the TRIG signal is input during measurement
Next measurement is not executed even if the TRIG signal from an external device is input during
measurement. Set whether or not to notify an external device that TRIG signal input was not accepted.
X MENU mode - [System] - [Measure] - [Trig in measure]
Operation Conditions during Startup
Set the type of the bank data and display screen to be displayed when the Controller is started up.
X MENU mode - [System] - [Startup]
The ENABLE signal is a control signal for indicating that the ZFX-C is ready to accept a measurement trigger or a
command from an external device. External devices monitor the ON/OFF timing of this ENABLE signal to input the
measurement trigger or commands to the ZFX.
Setting value Description
OFF The ERR signal does not turn ON even if the TRIG signal turns ON during measurement.
ERR ON The ERR signal turns ON when the TRIG signal turns ON during measurement. (default
value)
The ERR signal turns OFF when the next TRIG signal is input at the correct timing.
Setup Item Description
Startup Bank Group
Sets the bank group No. to be displayed when the Controller is started up. (default value: 0)
When bank groups 1 to 31 are selected, start up the Controller with the SD card contain-
ing the corresponding bank data attached.
Startup Bank Sets the bank No. to be displayed when the Controller is started up.
Range: 0 to 31 (default value: 0)
Startup screen Set the screen to be displayed in the RUN mode when the Controller is started up.
Range: Individual results (default value), the saved screen
When the selected display screen is inappropriate as a display target, All results/Region is
displayed as the default screen.
(Example: When no measurement items are registered)