PCX SMS AND PCX 256 SYSTEM MANUAL
Page: 148 RINS871-3
APPENDIX D: INPUT TYPES
Input Types
Number & Type Operation
00 Unused
Factory default
Input is programmed out of operation.
01 Fire
Active at all times
Audible response: Full (differentiated).
Communicator: ‘Fire’ signal
02 Gas
Active at all times
Audible response: Full (differentiated)
Communicator: ‘Gas’ signal
03 HU
Active at all times
Audible Response: Full (differentiated)
Communicator: ‘Hold Up’ and ‘Input HU’ signals
04 Silent HU
Active at all times
Audible Response: None
Communicator: ‘Hold Up’ and ‘Input HU’ signals
05 Tamper
When disarmed:
Audible Response: Internal only
Communicator: ‘Tamper’ signal
When armed:
Audible Response: Full (differentiated)
Communicator: ‘Tamper’ and ‘Intruder’ signals
06 Immediate
Active when armed
Audible Response: Full
Communicator: ‘Intruder’ signal
07 Entry/Exit (EE)
Active when armed – initiates entry timer if system not disarmed before entry time
expires: Audible Response: Full. Communicator: ‘Intruder’ signal
08 Access (A)
Active when armed, except during entry time
Audible Response: Full
Communicator: ‘Intruder’ signal
09 A (Part EE)
When fully armed, acts as Access input, as above
When part armed, acts as Entry/Exit input, as above
10 EE (Part A)
When fully armed, acts as Entry/Exit input, as above
When part armed, acts as Access input, as above
11 PTS
Active during exit time to complete arming procedure
No audible or communicator response.
Note: May be used to act as ‘doorbell’ by use of ‘chime’ attribute.
12 Switcher
Active at all times
No audible or communicator response
Triggers associated output or switches other equipment
13 24 Hour
When armed:
Audible Response: Full
Communicator: ‘Intruder’ signal
When disarmed:
Audible Response: Programmable
Communicator: ‘Day Alarm’ signal
15
Sub Part
Control
Input is allocated by system software and cannot be reprogrammed to a different
type, though relevant attributes may be adjusted.
(Not available on PCX 26/SMS)