PCX SMS AND PCX 256 SYSTEM MANUAL
Page: 150 RINS871-3
APPENDIX E: OUTPUT TYPES
Type Active Restore
0000 Not Used
0001 Fire
At alarm When a valid code is entered
0002 Hold Up Any
At a HU or Duress alarm
(This includes keypad HU)
When a valid code is entered
0003 Intruder Any
At alarm, while system is
disarmed
At first valid code entry
0004 Final Arm All*
When system is FULLY armed At code entry to disarm
0005 Misoperation Any (Abort)
When system is silenced after
any ‘intruder’ output is
triggered
After 2 minutes
0006 Confirmed Any
When further input active in
any partition after ‘intruder’
alarm
At next code entry
0007 Tamper Any
Any tamper alarm At code entry to silence
0008 Duress
At a Duress alarm (i.e. from a
keypad)
When a valid code is entered
0009 HU Device Any
At alarm on a HU input only When a valid code is entered
0010 Gas
At alarm When a valid code is entered
0011 Arm Fail
Pre-set time after start of exit
time, if exit procedure is not
complete
At code entry to rearm
0012 Entry Deviation
When deviation from entry
route occurs, during entry time
At code entry to disarm
0013 Secure Intruder Any
At alarm, after exit time started,
until disarm
At first valid code entry
0014 Bell Any
When alarm live
When alarm silenced or when
siren timer expires
0016 Strobe Any
When alarm live
When alarm silenced or when
strobe timer expires
0017 Omit Rearm Any
At rearm at end of confirm time
if an input in fault is isolated
When system disarmed
0018 Unconfirmed Any
Any intruder or Tamper alarm At code entry to silence
0019 Can All Arm*
If all inputs and technical faults
in system are clear. Also once
entry time has started
If fault exists, and after final
arm
0020 Exit Starts All*
At start of exit time to arm
LAST partition
At code entry to disarm FIRST
partition (i.e. no longer fully
armed)
NOTE: For ‘exit starts’ to be entered in system logs, the site option ‘Confirmed when…’ must be
set to ‘exit start’
0021 Exit Starts Any
When exit time starts to arm
FIRST partition
At code entry to disarm LAST
partition
0022 Final Arm Any
When FIRST partition is armed
At code entry to disarm LAST
partition
0023 Strobe Set Fail
Works similar to output 016, but also fires if the set fail timer
expires.
0025 Keyswitch unset
This output turns on for 5 seconds when the system is disarmed
via a keyswitch input (either pulsed or latched keyswitch)
0026
Set with Omit (Not on
PCX 256)
Activates when inputs are omitted on an arming mode
0031 Entry*
Live during any exit time
0032 Exit*
Live during any entry time
0033 Entry/Exit
Live during any entry or exit time
0034 Lights
When exit or entry timer starts
20 seconds after arm/disarm