PCX SMS AND PCX 256 SYSTEM MANUAL
Page: 84 RINS871-3
Use Level Arm*
If ‘YES’: The system becomes a ‘level arm’ (Having one partition set only at any one
time, e.g. part sets). If ‘NO’: The system becomes a ‘partition’ system (setting more
than once area at a time)
Confirmed When
Final Arm: Confirmed signal only available after the system is armed.
Exit Starts: Confirmed signal only available after the exit time has started.
Note: ‘Exit Starts’ must be selected in order for it to be entered in the logs.
AutoSet Force*
If ‘YES’ when autoset is in use (this is only available in the ARM software) the panel
will still set even if an input is open at the time.
Restrict PIN Use
If ‘YES’ the system prevents a pin code being entered on the Entry Time, but allows
the system to be silenced once in alarm.
Invert ATE O/Ps
If ‘YES’: ‘Positive Removed’ If ‘NO’: ‘Positive Applied’
Common Exit
Mode*
If set to ‘YES’, this will automatically select the ‘highest’ exit mode for all partitions.
(0 = Timed, 1 = Final Door, 2 = Timed/Final Door, 3 = PTS).
For example, if Partition C is selected as Final Door and the rest of the partitions are
selected as Timed, then because Final Door is ‘higher’ than Timed (Final door is 1
and Timed is 0 in the programming), all partitions will be set to Final Door.
If set to ‘NO’ the Exit Modes will be individually programmable to each partition.
Flexi Unset
If set to ‘YES’, this will allow all codes with Flexi-Arm attribute enabled to pick and
choose which partitions to arm/disarm during entry time.
2 Key HU
Selects whether the ‘2 key HU’ function at the keypad is live, and if so, whether
signalled only, audible only or both. If ‘YES’: The and keys, pressed
simultaneously, will generate a Duress Alarm.
ATE Inputs
Permits selection of inputs on ‘plug on’ communicator to suit ‘STU’ (including Red
Care Reset), ‘DigiCom’ (including Telback), ‘Relay Interface Monitoring’ or ‘Not
Used’.Note: This option must be set to ‘STU’ or ‘Digi’ in order for Line Fault, etc.
monitoring to function.
* NOT AVAILABLE ON PCX 26/SMS
Visual Keypad Programming Procedure
SITE OPTIONS
Site Options
Using the mand Pkeys, scroll to ‘SITE
OPTIONS?’ Press the Okey
Arm with Fault
Enter : for No
Enter : for Yes
Press the Okey. Repeat for all other options until:
2 Key HU
Enter : for ATE Enter : for Digi
Enter #: for Relay Enter : for None
Press the Okey. Repeat for ATE Inputs.