PCX SMS AND PCX 256 SYSTEM MANUAL
Page: 72 RINS871-3
13.13 Volume Control
The Volume Control function applies to the loudspeaker output only. Volume levels at the keypad are
programmed individually – please see page: 41.
13.13.1 Code Stops Sound
If this function is enabled, then once an alarm has been generated (even if the code is not programmed for
that partition) the alarm will be silenced, and a ‘Misoperation (Abort) signal’ will be sent, but the partition will
still be armed until a valid user that controls that partition is entered.
13.13.2 E / E Keypads Only
If there is a speaker connected to the SPK output of the PCX system the entry and exit tones will be heard
through the speaker. If you would like Entry and Exit tones to be heard on only the keypad and not the
speaker then enable this function.
13.13.3 Alert Kps Only
If this function is enabled then any Alert tones will be heard on the Keypad only and not the speaker.
Visual Keypad Programming Procedure
VOLUME CONTROL
Volume Control
Using the mand Pkeys, scroll to ‘VOLUME
CONTROL? Press the Okey
Partition Volume
Use the numeric keys select the volume level required
for Entry and Exit tones for each partition, once
selected, press the Okey to go to the next.
Alarm
Use the numeric keys to select the volume level
required for Alarm Tones
Press the Okey
Repeat for Fire, Tamper, Disarmed, Chime and
Intelligent Arm tones. Press the Okey
Code Stops Sound
Enter : for No
Enter : for Yes
Press the Okey