PCX SMS AND PCX 256 SYSTEM MANUAL
RINS871-3 Page: 85
13.18 Engineer Reset Options
The Engineer Reset Options are used so that once an alarm has occurred; the PCX system can only be
reset by an engineer code, anti code or red care reset from the alarm receiving centre.
Option Function
Engineer Restore
of Intruder
Following an intruder alarm, an engineer must reset the system before it can be used
again. Please select ‘UK Intruder’ to enable this, ‘Secure Intruder’ should not be
used. This will not interfere with the generation of an emergency alarm.
Engineer Restore
of HU
Following a Hold Up, Input HU or Duress alarm, an engineer must reset the system
before it can be used again. This will not interfere with the generation of a Fire or Gas
(emergency) alarm.
Engineer Restore
of Tamper
Following a Tamper alarm, an engineer must reset the system before it can be used
again. This will not interfere with the generation of an emergency alarm.
Engineer Restore
of Soak
In the event of an input with the ‘soak’ attribute triggering whilst the system is armed,
the system must be reset by an engineer before it can be used again. This will not
interfere with the generation of an emergency alarm.
Engineer Restore
of Confirmed
Following a confirmed alarm, an engineer must reset the system before it can be
used again.
Engineer Restore
of Faults
If selected, an engineers code will only be able to reset the following faults:
STU/ATE telecom fail, Modem fail, STU/ATE single path fail, Telecom line fail,
Battery disconnect, Batt charge, Batt load, Excessive charge, Battery critical, Device
fail.
Anti Code Restore
Enables the system to display an anti-code whilst awaiting an Engineer reset, which
can be used to generate a special reset code.
Visual Keypad Programming Procedure
ENGINEER RESET OPTIONS
Engineer Reset Options
Using the mand Pkeys, scroll to ‘ENGINEER
RESET OPTIONS?’ Press the Okey
Eng Reset Int
Enter : for No
Enter : for UK Intruder
Press the Okey.
Eng Restore HU
Enter : for No
Enter : for Yes
Press the Okey.
Repeat the above options for the restores: Tamper,
Soak, Confirmed, Faults and Anti Code Restore.
You will be returned to the Engineer Menu.