PCX SMS AND PCX 256 SYSTEM MANUAL
RINS871-3 Page: 75
Partition Stops
Enter : for Keypads
Enter : for Internal Sounders
Enter #: for Bells Only
Enter : for Digi
Enter : for Confirm
Press the Okey
Repeat the above 2 steps for each partition, and also
for Fire, Gas, HU and Disarm alarms
Press the Okey
You will be returned to the Engineer Menu
13.15 Change Outputs
Any output type may be programmed to any of the systems PGMs. PGMs must be used within their rated
capacity. See page: 23.
NOTE: The PGM Outputs CANNOT
be inverted.
13.15.1 PGM Output Types
Type Active Restore
0000 Not Used
0001 Fire
At alarm When a valid code is entered
0002 Hold Up Any
At a HU or Duress alarm
(This includes keypad HU)
When a valid code is entered
0003 Intruder Any
At alarm, while system is
disarmed
At first valid code entry
0004 Final Arm All*
When system is FULLY armed At code entry to disarm
0005 Misoperation Any (Abort)
When system is silenced after
any ‘intruder’ output is
triggered
After 2 minutes
0006 Confirmed Any
When further input active in
any partition after ‘intruder’
alarm
At next code entry
0007 Tamper Any
Any tamper alarm At code entry to silence
0008 Duress
At a Duress alarm (i.e. from a
keypad)
When a valid code is entered
0009 HU Device Any
At alarm on a HU input only When a valid code is entered
0010 Gas
At alarm When a valid code is entered
0011 Arm Fail
Pre-set time after start of exit
time, if exit procedure is not
complete
At code entry to rearm
0012 Entry Deviation
When deviation from entry
route occurs, during entry time
At code entry to disarm
0013 Secure Intruder Any
At alarm, after exit time started,
until disarm
At first valid code entry
0014 Bell Any
When alarm live
When alarm silenced or when
siren timer expires
0016 Strobe Any
When alarm live
When alarm silenced or when
strobe timer expires
0017 Omit Rearm Any
At rearm at end of confirm time
if an input in fault is isolated
When system disarmed