PCX SMS AND PCX 256 SYSTEM MANUAL
Page: 76 RINS871-3
Type Active Restore
0018 Unconfirmed Any
Any intruder or Tamper alarm At code entry to silence
0019 Can All Arm*
If all inputs and technical faults
in system are clear. Also once
entry time has started
If fault exists, and after final
arm
0020 Exit Starts All*
At start of exit time to arm
LAST partition
At code entry to disarm FIRST
partition (i.e. no longer fully
armed)
NOTE: For ‘exit starts’ to be entered in system logs, the site option ‘Confirmed when…’ must be
set to ‘exit start’
0021 Exit Starts Any
When exit time starts to arm
FIRST partition
At code entry to disarm LAST
partition
0022 Final Arm Any
When FIRST partition is armed
At code entry to disarm LAST
partition
0023 Strobe Set Fail
Works similar to output 016, but also fires if the set fail timer
expires.
0025 Keyswitch unset
This output turns on for 5 seconds when the system is disarmed
via a keyswitch input (either pulsed or latched keyswitch)
0026
Set with Omit (Not on
PCX 256)
Activates when inputs are omitted on an arming mode
0031 Entry*
Live during any exit time
0032 Exit*
Live during any entry time
0033 Entry/Exit
Live during any entry or exit time
0034 Lights
When exit or entry timer starts
20 seconds after arm/disarm
procedure completed
0035
Follow Input*
See page: 81.
When input triggers Dependant upon programming
0036 Shunt Fault* See Shunt Inputs - Page: 55
0037 Reset 1 (Viper Reset)
At code entry to arm After 3 seconds
At code entry to arm When disarmed
0038
Reset 2 (Viper
Arm/Disarm)
Re-triggers whenever an additional partition is armed
0039 PIR Latch 1
When armed (and in Walk
Test)
At alarm, or when disarmed
0040 PIR Latch 2
This is the inverse polarity to PIR Latch 1
0041 Mains Good
Output showing the mains is healthy
0042 Detr Indn Enable*
This output activates during walk test and also when a code is
entered to view indications – staying activated for the time for
which the indications are viewed.
0043 Follow Test
New output for alternative bell test by activating SAB
0044 Off During Test
New output for alternative bell test by activating SAB
0051 Telecom Line Fault
When Line Fault signalled by
communicator
When fault clears
0052 AC Fail
After pre-set time without
mains power
On restoration of mains
0053 Battery Faults
When battery disconnected or
load fail detected
At next valid code entry
0054 Low Volts
At fault When fault clears
0055 Global Fault 1
Activates if fault occurs only
when system is armed (Faults:
Modem, Battery, Fuse, Line,
Mains)
When all faults cleared
0056 Global Fault 2
Activates if fault occurs at any
time (Faults: Modem, Battery,
Fuse, Line, Mains)
When all faults cleared
0057 German Relay*
0058 Guard Code Used
When ‘guard’ code accepted After 60 seconds