PG-FP5 CHAPTER 6 USAGE IN STANDALONE MODE
R20UT0008EJ0400 Rev. 4.00 Page 131 of 240
Jul 15, 2010
Table 6-3. [Option Setting] Menu (3/3)
Main Menu Submenu Description
[Option Setting >] [OPBTx
x=0 to 8
] Displays the setting of the [Option bytes setting] box in the [Option bytes setting]
area on the [Advanced] tab in the Device Setup dialog box. If the [NEXT] button is
clicked, the display changes from OPBT0 to OPBTx.
Display example:
If FFFFFFE9 is specified for OPBT0 in the [Option bytes setting] area
OPBT0
FFFFFFE9
6.3.4 [Voltage Setting] menu
The [Voltage Setting] menu is used to check the voltage level setting used when programming the target device
currently connected to the FP5. The settings downloaded to the valid programming area are displayed. The settings
cannot be changed using this menu.
Table 6-4. [Voltage Setting] Menu
Main Menu Submenu Description
[Vdd ] Displays the value of VDD supplied to the target device connected to the FP5 in volts.
[Vdd2 ] Displays the value of VDD2 supplied to the target device connected to the FP5 in
volts.
[Vdd Source ] Indicates the source of VDD supplied from the target device as either of the following.
V
DD from PG: VDD is supplied from the FP5.
V
DD from device: VDD is supplied from the user system.
[Vdd Monitoring ] Displays the setting of the [Vdd monitoring] check box in the [Supply voltage] area
on the [Advanced] tab in the Device Setup dialog box.
on: Selected, off: Not selected
[FLMD0 Level ] The FLMD0 Level displays the voltage level of the FLMD0 signal.
[CLK Level ] Indicates the voltage level of the clock signal as either of the following.
VDD
VDD2
[RESET Level ] The Reset Level displays the voltage level of the RESET
¯¯¯¯¯¯
signal.
VDD
Also, when the [Enable target RESET] check box in the [Command options] area of
the device setup dialog [Advanced] is enabled, "VDD Reset TrigIn" is displayed.
[Serial Level ] Indicates the voltage level of the serial communication signals. The high level of the
serial communication signal is indicated as either of the following.
VDD
VDD2
[Voltage Setting >]
[Vpp ] Indicates the value of V
PP supplied to the target device connected to the FP5 in volts.
<R>

Table of Contents

Other manuals for Renesas PG-FP5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas PG-FP5 and is the answer not in the manual?

Renesas PG-FP5 Specifications

General IconGeneral
BrandRenesas
ModelPG-FP5
CategoryMotherboard
LanguageEnglish

Related product manuals