8.4.19 srec command
Uploads the program file in Motorola HEX format.
Input format
'srec' ((<code_start address> <code_length>) (<data_start address> <data_length>))
Description of the function
If a program file has been downloaded to a valid programming area, executing this command will upload the program
file in Motorola HEX format. If this command is executed without any options, the upload will be executed with the
address size used during downloading. If a program has not been downloaded, then "Invalid argument" will be
displayed. The starting address and number of bytes are designated as options.
start address: The starting address is designated as a hexadecimal number. If a PR5 file that support data flash
has been downloaded, then the code area and data area are designated.
length: The number of bytes is designated as a hexadecimal number. If a PR5 file that support data flash
has been downloaded, then the code area and data area are designated.
Example of usage
Command Screen output
srec Press 'return' to start/continue output.
srec 0 3fff Press 'return' to start/continue output.
srec 0 3ffff 400000 20000 Press 'return' to start/continue output.
After the command is executed, pressing the Return key will start the upload. See below.
S0030000FC
S325000000008100810081008100810081008100810081008100810081008100810081008100CA
S32500000020810081008100810081008100810081008100810081008100810081008100FFFF2D
:
S5030000FC
S70500000000FA