PG-FP5 CHAPTER 6 USAGE IN STANDALONE MODE
R20UT0008EJ0400 Rev. 4.00 Page 132 of 240
Jul 15, 2010
6.3.5 [Utility/Misc.] menu
The [Utility/Misc.] menu is used to reset the FP5 main unit, tune the LCD contrast, check the firmware version, check
the name and version of the PR5 file downloaded, check the name of the program file downloaded, and check the
checksum of program files. The settings downloaded to the valid programming area are displayed. The settings cannot
be changed using this menu.
Table 6-5. [Utility/Misc.] Menu
Main Menu Submenu Description
[Utility ] Displays the FP5 Manager mode settings.
<Display example>
Std. mode Sec
Std. mode unSec
[Reset FP5 >]
Pressing the ENTER button resets the FP5.
[Set LCD Contr. >]
Tunes the contrast in the message display. After pressing the ENTER button, the
contrast can be tuned using the NEXT (darken) or CANCEL button (lighten). To
fix the contrast, click the ENTER button.
[FP5 F/W Version ] Displays the FP5 firmware version.
<Display example>
FP5 F/W Version
V1.00
[PRM Name ] Displays the name of the PR5 file stored in the FP5 valid programming area.
<Display example>
PRM Name
78F1166
[PRM File Version ] Displays the version of the PR5 file stored in the FP5 valid programming area.
<Display example>:
PRM File Version
V1.00
[HEX File Name ] Displays the name of the program file stored in the FP5 valid programming area.
<Display example>
HEX File Name
Sample.hex
”n.a.” is displayed if the program file is invalid.
[Utility/Misc. >]
[File Checsum ] File Checksum will display the results of executing the programming GUI [F
ile] menu
-> [C
hecksum...]command.
<Display example>
File Checsum
623E (ARITHM.)