8.5.2 con command
Executes the processes from “transition to the flash memory programming mode” to “signature verification”.
Input format
'con'
Description of the function
Executes the processes from “transition to the flash memory programming mode” to “signature verification”. In order to
use this command, “manual” (off) must be set with the autocon command beforehand.
Example of usage
Command Status Status LED Message display Screen output
Display while executing the command BUSY Connecting:
Display after executing the command
[When completed normally]
PASS
Returns to the display before
executing the command.
PASS
Dxxxxxxx>
con
Display after executing the command
[When terminated abnormally]
ERROR
ERROR: xxx
xxxxxxxxxxxxxxxx
ERROR(Exxx): <text>
8.5.3 dcon command
Executes the process to end the flash memory programming mode.
Input format
'dcon'
Description of the function
Executes the process to end the flash memory programming mode. In order to use this command, "manual" (off) must
be set with the autocon command beforehand.
Example of usage
Command Status Status LED Message display Screen output
Display while executing the command BUSY Disconnecting: con
Display after executing the command PASS
Returns to the display before
executing the command.
Device disconnected.

Table of Contents

Other manuals for Renesas PG-FP5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas PG-FP5 and is the answer not in the manual?

Renesas PG-FP5 Specifications

General IconGeneral
BrandRenesas
ModelPG-FP5
CategoryMotherboard
LanguageEnglish

Related product manuals