PG-FP5 CHAPTER 8 USAGE COMMUNICATION COMMANDS
R20UT0008EJ0400 Rev. 4.00 Page 146 of 240
Jul 15, 2010
(1/2)
Command Screen output
conf progarea 4x4 [If there are four sections before the command is executed]
OK
INFO: Same setting. Configuration is not changed.
[If there are eight sections before the command is executed]
OK
INFO: New configuration has been set.
INFO: Progarea data is not valid any more.
Number of Program areas: 4 Active Program Area: 0
Size of Program Areas (Code / Data):
Area 0: 0x400000 / 0x020000
Area 1: 0x400000 / 0x020000
Area 2: 0x400000 / 0x020000
Area 3: 0x400000 / 0x020000
Area Filename Date Time Range CRC
*0 {unknown data}
1 {unknown data}
2 {unknown data}
3 {unknown data}
Checking Progareas.........
No invalid data found.