SERVICE MODE TABLE
SM 5-47 G104
Service
Tables
SP3-XXX (Process)
3001 [Vt Display] Vt Display ([Color])
3001 001 [K] *EGB
3001 002 [M] *EGB
3001 003 [C] *EGB
3001 004 [Y] *EGB
Displays the output voltage of TD sensor for
each color.
[0.00 to 5.00 / 0.01 / 0.01 V/step]
3002 [Vcnt Current] Current Vcnt Display ([Color])
3002 001 [K] *EGB
3002 002 [M] *EGB
3002 003 [C] *EGB
3002 004 [Y] *EGB
Displays the current Vcnt for each color.
[0.00 to 5.00 / 3.00 / 0.01 V/step]
[Vcnt Initial] Initial Vcnt Display ([Color])
3002 005 [K] *EGB
3002 006 [M] *EGB
3002 007 [C] *EGB
3002 008 [Y] *EGB
Displays the initial Vcnt for each color.
[0.00 to 5.00 / 3.00 / 0.01 V/step]
3003 [Vtref Current] Current Vtref Display ([Color])
3003 001 [K] *EGB
3003 002 [M] *EGB
3003 003 [C] *EGB
3003 004 [Y] *EGB
Displays the current Vtref for each color.
[0.00 to 5.00 / 3.00 / 0.01 V/step]
[Vtref Initial] Initial Vtref Display ([Color])
3003 005 [K] *EGB
3003 006 [M] *EGB
3003 007 [C] *EGB
3003 008 [Y] *EGB
Displays the initial Vtref for each color.
[0.00 to 5.00 / 3.00 / 0.01 V/step]
3011
[T. Sensor Init.] Toner Density Sensor Initial Setting
(Agitation Time, TS Target: Toner Sensor Target Value, [Color])
3011 001 Agitation: [K] *EGB
3011 002 Agitation: [M] *EGB
3011 003 Agitation: [C] *EGB
3011 004 Agitation: [Y] *EGB
Adjusts the agitation time for the developer
for each color.
[0 to 300 / 65 / 1 sec/step]
3011 005 TD Target: [K] *EGB
3011 006 TD Target: [M] *EGB
3011 007 TD Target: [C] *EGB
3011 008 TD Target: [Y] *EGB
Adjusts the TS initial target voltage for each
color.
[0.00 to 5.00 / 2.50 / 0.01 V/step]
3021 [Vt Shift] Vt Shift Setting ([Color])
3021 001 [K] *EGB
3021 002 [M] *EGB
3021 003 [C] *EGB
3021 004 [Y] *EGB
Adjusts the Vt shift rate for each color.
[0.00 to 5.00 / 0.75 / 0.01 V/step]