Specifications and Site Requirements
Electrical Specifications
QuickStick HT User Manual 143
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Figure 4-16: QSMC Motor Controller Electrical Connections
NOTICE Hot-plugging of either power source to the motor controller
is not recommended.
Table 4-13: QSMC Motor Controller Connections
Label Description Connector Type
STATOR SENSE Motor block control signals M12 Eurofast, 6-Pin, Female
ETH (NO PoE) Ethernet – 10/100/1000 BaseTx M12 Eurofast, FKFDD, 4-Pin, Female
UP STREAM RS-422 motor communications M8 Nano-Mizer
®
, 4-Pin, Male
*
* When using an NC LITE, MagneMotion recommends connecting the upstream connections to the odd num-
ber connectors on the node controller and the downstream connections to the even number connectors.
LVDC (logic power) 24V DC ±5%,
0.6 A typical, 0.75 A max
M12 Eurofast, FSFD 4.4, Male
DOWN STREAM RS-422 motor communications M8 Nano-Mizer, 4-Pin, Male
*
STATOR DRIVE Motor block phase power 16S-1S, 7-Pin, Female
HVDC (motor power) 270V DC min, 400V DC max,
5 A typical, 15 A max
A-size Powerfast
â„¢
, 3-Pin, Male
Ground M6 threaded stud
â€
†MagneMotion requires grounding the QSMC through the ground stud using a minimum of 14 AWG wire.
Status Indicator
Front View
Stator
Ethernet
RS-422
Stator
HVDC Power
Power Indicator
LVDC Power
Ground
Sense Drive
Upstream
RS-422
Downstream