Installation
Check-out and Power-up
224 MagneMotion
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
10. Upload the configuration, image, and type files to each node controller (see the Node
Controller Interface User Manual, MMI-UM001).
11. When using QSHT 5700 inverters:
A. Create a MICS file (see Ethernet Motor MICS File on page 89).
B. Upload the MICS file to all node controllers (see the Node Controller Interface
User Manual, MMI-UM001).
C. Cycle logic power to the motors to force the motors to request their network
provisioning.
12. Program the masters and slaves for the motors. See the Node Controller Interface User
Manual, MMI-UM001, for details.
13. Review the log files for each node controller to make sure that the system has been
programmed and configured properly (see the Node Controller Interface User Man-
ual, MMI-UM001).