2-7
PERIODIC
MAINTENANCE
AND
TUNE-UP
PROCEDURES
FUEL LINES
Inspect
at
Initially
1 000
km
(2 months) and
Every 6 000 km (12 months)
Replace Every 4 years
OIL
PUMP
Inspect
at
Initially
1 000 km (2 months) and
. Every 6 000 km (12 months)
The engine oil
is
fed by the oil pump
to
the engine. The
amount
of
oil fed
to
it
is
regulated by engine
speed
and the oil
pump control lever which
is
controlled
by
the amount
of
throttle
opening.
Check the oil pump in the following manner
to
confirm
correct operation
for
all
throttle
valve opening positions.
• Remove the magneto cover.
• Remove the oil pump inspection
cap.
• Remove the air cleaner
cap.
• Turn the
throttle
grip gradually and
raise
the
throttle
valve
CD
until
the valve's lower end aligns
with
the line
CID
on
the
carburetor bore. Hold the
throttle
in this position.
• Adjust the oil pump cable adjuster
<ID
so
that
the line ® on
the oil pump lever aligns
with
the notch line @ on the body.
CAUTION:
Oil pump cable adjustment must
be
done after
throttle
cable
adjustment.
@
CD
Throttle
valve
CID
Yz
opening
mark
Right carburetor
CID
Yz
opening
mark
Full close mark
@ Reference mark