E6582233
E-14
5
The inverter was factory-configured by default so that shorting terminals F-CC and terminals R-CC
simultaneously would cause the motor to slow down to a stop.
Using the parameter , however, you can select between forward run and reverse run.
5.8 Maximum frequency
: Maximum frequency
Function
1) Programs the range of frequencies output by the inverter (maximum output values).
2) This frequency is used as the reference for acceleration/deceleration time.
Output frequency
(Hz)
When  =80Hz
When  =50Hz
80Hz
50Hz
0 100% Frequency setting signal (%)
This function determines the value
in line with the ratings of the motor
and load.
Maximum frequency cannot be
adjusted during operation.To
ad
j
ust
,
first sto
p
the inverter.
If  is increased, adjust the upper limit frequency  as necessary.
If  or  is changed and  trip occur at the frequency that is higher than , the following remedies
are effective.
Increase the deceleration time .
If overvoltage limit operation  is set to 0,2 or 3, decrease the over voltage stall protection level
 (ex.  =  )
[Parameter setting]
Title Function Ad
j
ustment ran
g
e Default settin
g
 Maximum frequency 30.0-400.0 (Hz) 50.0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-nC3E and is the answer not in the manual?

Toshiba TOSVERT VF-nC3E Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-nC3E
CategoryInverter
LanguageEnglish

Related product manuals