24 Operation principle and hardware description
and main part of the generator power is fed by the generator stator. Principle of the doubly-
fed induction generator with a wind turbine converter can be seen in the figures below.
Wind turbine system with low voltage stator (690 V)
Wind turbine system with medium voltage stator (> 1000 V)
R2
ABRU
R2
ACBU
MCB1MCB3
LCLISU
MCB2
INU
MCB
Turbine
transformer
Doubly-fed
induction
generator
WIND TURBINE CTRL
Rotor bearing
Pitch drive
Gearbox
Medium
voltage
switchgear
Low voltage
switchgears
Wind turbine converter
MCB EMERGENCY
OPEN CTRL
Rotor
hub
CONVERTER CTRL
MCB CTRL
MCB1 ON/OFF
CTRL
MCB3 ON/OFF
CTRL
Brake
system
Blades
R2
ABRU
R2
ACBU
MCB3
LCL
ISU
MCB2
INU
MCB
CONVERTER CTRL
Pitch drive
Gearbox
Turbine
transformer
High voltage
switchgear
WIND TURBINE CTRL
Brake
system
Doubly-fed
induction
generator
Wind turbine converter
Medium
voltage
switchgear
Rotor
hub
Blades
Rotor bearing
MCB EMERGENCY
OPEN CTRL
MCB CTRL
MCB3 ON/OFF
CTRL